Tested Manifold Pressure Sensor (MPS) with Actron Vacuum Pump to 26 in Hg for 15 minutes without any leakage. Measured primary coil resistance of MPS (outer two leads) and found 98 ohms (spec 90 ohms). Measured secondary coil resistance of MPS (inner two leads) and found 382 ohms (spec 350 ohms). Thankfully, MPS is in good shape! However, spare from parts car has vacuum leak so I'm on the look out for a good spare.
With AAR fixed, set Idle Speed Limiter gap and tested vacuum side with Actron to 26 in Hg for 10 minutes without leakage.
Cold start valve has been bypassed with fuel by previous owner. Measured cold start valve coil resistance and found 4.8 ohms (spec 4.2 ohms). I will check for leaks when injectors are tested.
Valves adjusted. No "white" spot for #2/4 TDC, so created right angle cardboard template to find it and mark it with white-out. Location verified using spare fan and counting blades. New valve cover gaskets installed after scraping/cleaning old ones glued onto cover:(